  Fire
Alarm Panels |

Fire Alarm Panel - Conventional

These series of Microprocessor based fire alarm panels are an upgraded
version which provides a reliable and cost effective solutions to fire
detection, from small to large size installations which have 2, 4, 6, 8 &
could go up to 60 zones of selecting models and features.
These
units have been designed to offer high standards of performance, reliability
and quality and comply with IS 2189 : 1999 and tested by the ERTL (N).These
series panels are specially suited for the small offices, workplaces, small
& high rise buildings.

The
Microprocessor based fire alarm panels provides a reliable and cost
effective solutions to fire detection, from small to large size
installations which have 2, 4, 6, 8 & could go up to 60 zones of
selecting models and features.
These units have been designed to
offer high standards of performance, reliability and quality and comply with
IS 2189 : 1999 and tested by the ERTL (N).These panels are specially suited
for the small offices, workplaces, small & high rise buildings.

Fire Alarm Panel - Addressable
Addressable panels are usually much
more advanced than their conventional counterparts, with a higher degree of
programming flexibility and single point detection.
SIGNALING
LINE CIRCUIT LOOPS
Panels usually have a number of signaling line
circuit loops - usually referred to as loops or SLC loops - ranging between
one and thirty. Depending on the protocol used, a loop can monitor and
control several hundred devices. Some protocols permit any mix of detectors
and input/output modules, while other protocols have 50% of channel capacity
restricted to detectors/sensors and 1/2 restricted to input/output modules.
Each SLC polls the devices connected, which can number from a few devices to
several hundred, depending on the manufacturer. Large systems may have
multiple SLCs, and SLCs are further divided into sub-groups through the use
of fault-isolation modules.
Each device on a SLC has its own
address, and so the panel knows the state of each individual device
connected to it. Common addressable input (initiating) devices include:
->
Smoke detectors
-> Manual call points or manual pull stations
->
Notification appliances (Simplex systems with TrueAlert signals only)
->
Responders
-> Fire sprinkler system inputs
-> Switches
->
Flow control
-> Pressure
-> Isolate Standard switches
->
Addressable output devices are known as relays and include
->
(Warning System/Bell) Relays
-> Door Holder Relays
->
Auxiliary (Control Function) Relays
-> Relays are used to
control a variety of functions such as
Switching fans on or off
->
Activating fire suppression systems
-> Activating notification
appliances
-> Shutting down industrial equipment
->
Recalling elevators to a safe exit floor
-> Activating another fire
alarm panel or communicator.
Listing
UL , CE, FCC

Fire Alarm Panel - VESDA
 |
 |
VESDA is a very advanced and reliable very
early fire detection system which detects a potential fire very early giving
you that extra time before the fire becomes big and difficult to control and
thus saves you a lot of damage, downtime and cost of suppression release.
It's a fire detection system that offers the earliest possible warning of a
potential fire. A system that will ensure business continuity and freedom
from nuisance alarms. A system that can adapt to the unique characteristics
of any given environment. One that delivers high performance through its
high quality design and its dedicated global sales and distribution
channels. With hundreds of thousands installed globally, the VESDA name has
become synonymous with high performance very early warning smoke detection.
It is the product chosen when reliable performance is crucial.
VESDA
Air Sampling Smoke Detection Systems are recognized as the global market
leader and provide very early warning smoke detection solution all around
the world. VESDA detectors have been proven for decades in industries such
as telecommunications, power generation, warehousing, clean rooms, and
manufacturing/storage services.
VESDA is an ideal solution
when:
-> Business continuity is very important
-> Smoke is
very difficult to detect
-> Area to be protected is difficult to
access.
-> Unobtrusive detection is needed .
-> Fast
evacuation is difficult.
-> Environment conditions are difficult.
->
Suppression system requires different levels of warning at different stages
of fire.
 
Fire Detectors |

Optical Smoke Detector
Conventional Photoelectric Smoke Detector and Smoke cum Heat
Detector All of detectors meet the requirements of UL 268 and EN
54-7/5 for use in Fire Alarm signaling systems. They are intended for use in
2-wire/4 wire Class A or B supervised zone circuits.
The AD 333
Series detectors are subject to panel compatibility limits and compliance
with corresponding NFPA 72E standards, local codes, and ordinances.

Heat Detector

Heat detectors meet the requirements of UL 268 and EN 54-7/5 for use in Fire
Alarm signaling systems. They are intended for use in 2-wire/4 wire Class A
or B supervised zone circuits. The Series detectors are subject to panel
compatibility limits and compliance with corresponding NFPA 72E standards,
local codes, and ordinances.
The conventional series of Heat
detectors were designed with precise CPU control and thermistor detection.
Its state of the art combination of "Rate of Rise" and "Fixed
Temperature" ensures the best quality of heat detection in all
environments.

Stand Alone Detector

Standalone Detector Series photoelectric smoke detectors are designed in
accordance with UL-217, EN-146045 IC & BS 5446 and manufactured under
the best quality control. The series alarm are adopted the reliability
UL-certificated infrared components. It alarms also act as a smoke sensor
and/or a 1350F heat detector at the same location.

Heat Detector

Heat detectors are designed & manufactured under the best quality
control. It act as a fix temperature & issue the signal to control panel
at 1350F .
 
Fire System Accessories |

Manual Call Points

The Manual Call Point is tough, durable & highly visible.A Alarm LED/s
is provided inside the Call Point to indicate the Alarm condition.

Sounders

The Electronic sounder is designed for use within fire alarm systems,
security systems and industrial signaling systems. Combined sounder and
beacon provides an audio-visual warning which is suitable for place which
requires high sound output and visual indication.

Remote Indicating Lamp

The unit is designed to ensure that Alarm Signal can be actually transmitted
to all locations. To prevent any missing signal specially for the close